During the installation and commissioning of the tube press, there are many details to be noted. The matters needing attention in the tube press are handling, installation, micrometer, pressure adjustment, oil injection, power connection, and mold opening speed adjustment.
 
1. Handling: The pipe pressing machine is suitable to be transported by forklift, and the bottom of the pipe pressing machine is stressed. The pipe pressing machine is strictly prohibited from being inverted. It is strictly forbidden to lift the pressure pipe head and the motor and electrical box parts.
2. Installation: The tube press should be placed horizontally on a stable foundation and grounded. Wuzhou Hydraulic: Precautions for installation and commissioning of pressure tube machine
3, micrometer: used to adjust the amount of shrinkage of the crimping hose, counter-clockwise half-week pressure into 1mm, clockwise half a week less pressure into 1mm.
4. Pressure adjustment: The maximum pressure of the tube press system is 31.5Mpa, which is adjusted by the relief valve. The pressure is increased clockwise, and the pressure is reduced counterclockwise (it has been adjusted at the factory and can be adjusted if necessary). Wuzhou Hydraulic: Precautions for installation and commissioning of pressure tube machine
5. Fill the oil: Open the fuel tank cap and add 68# anti-wear hydraulic oil to the oil tank 2/3 position.
6. Power-on: Connect the power cable to the power supply specified by the pressure tube machine, start the motor to observe the steering, and the motor steering should be consistent with the direction marked by the motor. Wuzhou Hydraulic: Precautions for installation and commissioning of the tube press If the direction of the motor is not the same as the direction of the mark, please change the position of the two power lines.
7. Mold opening speed adjustment: the speed of the mold opening speed is controlled by the diverter valve, clockwise adjustment, the opening speed is increased, counterclockwise adjustment, the opening speed is slowed, but the opening speed is too fast, the noise will increase. The optimal value is not more than 10Mpa (it has been adjusted at the factory and can be adjusted if necessary).

The installation and commissioning of the tube press can not be ignored. Perhaps it is the sloppyness of this point that causes the use quality of the tube press to decrease, and the life expectancy is shortened, which will directly affect the benefits of the enterprise.

Categories

Contact

CONTACT US

Contact: Ms. Sabella Wei

Phone: +86 022-8385-9963

Tel: +86 158-2292-5523

Whatsapp: +86 158-2292-5523

Email: henghua@hhgpipe.com

Add: No. 3302, Building 9, Boxuan Garden, Dagu South Road, Hexi Dist., Tianjin, China (Mainland)